As part of our process for identifying the correct quantities of E-MetroTel-provided equipment required for a legacy CS1000 migration, the following details are required:
- Is this currently a single or multi-site system? If currently a multi-site system, then the remaining questions need to be answered for each site.
- Will the final E-MetroTel architecture be deployed as a single system, or will systems be deployed on multiple sites?
- Existing System hardware specifics (choose one per site):
Meridian 1 Option 11, CS1000 (wall-mounted 10-slot cabinets) Meridian 1 Option 51/61/81, CS1000M SG/MG (standalone 16-slot cabinets) CS1000E (19 inch. rack-mounted 4-slot or 10-slot cabinets) - Software Version: _________________
- Phone/Trunk Quantities:
Phone/Trunk Type Existing To be Re-used New Quantities Required IP phones Digital phones Analog phones SIP Trunks DTI/PRI trunks Analog trunks M1250/M2250 Attendant Consoles
Note: If you are unsure of answers to questions 3 or 4 and/or the first column of question 5, E-MetroTel can assist in obtaining this information directly from various CS1000 overlays. The Overlay and Commands to retrieve the information are shown below. E-MetroTel can also provide instructions on how to capture the command output into files that can be sent to our team to ascertain the required information.
Information | CS1000 Overlay | Command |
Software Version | 22 | REQ ISS |
IP phones | 117 | STAT ISET ALL |
Digital phones | 117 | INV PRT SETS |
Analog phones | 81 | REQ LST or CNT; CUST, FEAT SETS and REQ LST or CNT; CUST, FEAT DTN |
SIP Trunks | 22 | REQ SLT; SIP ACCESS PORTS |
DTI/PRI trunks | ||
Analog trunks | 81 | REQ PRT; TYPE COT, TYPE DID, TYPE TIE |
M1250/M2250 Attendant Consoles | 20 21 | REQ PRT; TYPE 2250 REQ PRT; TYPE ATT |